Zemic HM9B
Zemic HM9B load cell are available in the capacities 10t to 50t, alloy steel construction, nickel plated, hermetically welded, oil-proof, waterproof and anti-corrosive gas and medium making it suitable for all kinds of environments. Dual shear beam, suitable for electronic truck scales, railway scales and other electronic weighing devices. It is safety and anti-explosion product that can be used in atrocious weather and hazardous areas.
Sparepart Timbangan
FEATURES : ZEMIC HM9B LOAD CELL
Capacity : 10t t0 50t High accuracy Alloy steel construction Easy installation, reliable performance With OIML approval
SPECIFICATIONS : ZEMIC HM9B LOAD CELL
Capacity t 10/20/25/30/40SE/40/50 Accuracy C1 C2 C3 A5M B10M Approvals OIML R60 C3 Maximum number of
verification intervals n max 1000 2000 3000 5000 10000 Minimum load cell
verification interval v min Emax/3000 Emax/5000 Emax/7500 Emax
/15000 Emax
/10000 Combined error %FS ≤±0.050 ≤±0.030 ≤±0.020 ≤±0.026 ≤±0.050 Creep %FS/30min ≤±0.038 ≤±0.024 ≤±0.016 ≤±0.017 ≤±0.040 Temperature effect
on sensitivity %FS/10℃ ≤±0.028 ≤±0.017 ≤±0.011 ≤±0.013 ≤±0.040 Temperature effect
on zero %FS/10℃ ≤±0.047 ≤±0.023 ≤±0.015 ≤±0.014 ≤±0.020 Output sensitivity mV/V 2.0±0.002 2.3±0.002 2.4±0.002 1.9±0.002 1.8±0.002 Input resistance Ω 700 ±7 775 ±5 750 ±7 Output resistance Ω 700 ±7 Insulation resistance MΩ ≥ 5000 (50V DC) Zero balance %FS 1.5 Temperature, compensated ℃ -10 ~ +40 Temperature, allowed ℃ -35 ~ +65 Excitation, recommended V 5 ~ 12 (DC) Excitation, max V 18 (DC) Safe overload %FS 150 Ultimate overload %FS 300